Skip to main content
. 2023 Jun 22;16:2633–2642. doi: 10.2147/IJGM.S404834

Table 3.

Lung Function: Average Measures and Percentage Predicted of FEV1, FVC, PEFR

Baseline (Mean ± SD) 3 Months (Mean ± SD) PFT Overtime Intubation Status (Covariate)**
N= 99 N = 75 p value p value
FVC L 2.92 ± 0.97 3.12 ± 0.89 < 0.001 0.481
% 78.27 ± 22.57 85.29 ± 22.56 < 0.001 0.410
FEV1% L 2.43 ± 0.74 6.29 ± 31.45 < 0.001* 0.074
% 79.12 ± 20.23 87.99 ± 18.26 < 0.001 0.415
FEV1/FVC L 84.86 ± 8.35 86.36 ± 5.47 0.249 0.483
% 107.44 ± 11.11 109.00 ± 6.13 0.266 0.344
PEFR 96.72 ± 24.72 106.93 ± 21.76 < 0.001 0.245

Notes: *Wilcoxon test was used due to skewed distribution. **General Linear Model (GLM) was used. All significant p values in bold text.