Skip to main content
. 2022 Nov 3;143(7):4481–4490. doi: 10.1007/s00402-022-04671-3

Table 4.

Comparison of treatment outcome comparing patients who had two-stage revision for PJI in cemented and cementless THA

Variable Cementeda (n = 36) Cementless (n = 72) p value
Infection control
 Interim re-debridement 6 (17%) 7 (10%) 0.296
 Reinfection after reimplantation 8 (22%) 5 (7%) 0.021
Other complications
 Femoral fracture in the interim period 1 (3%) 2 (3%) 1.000
 Dislocation after reimplantation 6 (17%) 5 (7%) 0.128
 Periprosthetic femoral fracture after reimplantation 4 (11%) 0 (0%) 0.004
 Cup loosening 0 (0%) 1 (1%) 0.477
 Stem loosening 1 (3%) 1 (1%) 0.613

p values were calculated from chi-square test; bold—the significance level was p < 0.05

PJI periprosthetic infection; THA total hip arthroplasty

aCemented or hybrid total hip arthroplasty