Intra- and interobserver (2 observers) correlation of all parameters

Parameter Intraobserver reliability Interobserver reliability
ICC 95% CI ICC 95% CI
Preoperative radiograph
 LCAE 0.985 0.978–0.991 0.960 0.937–0.97
 AI 0.989 0.983–0.993 0.968 0.924–0.983
 AWI 0.970 0.954–0.981 0.819 0.721–0.882
 PWI 0.986 0.979–0.991 0.946 0.917–0.965
Intraoperative fluoroscopic imaging
 LCAE 0.969 0.952–0.980 0.871 0.784–0.921
 AI 0.976 0.963–0.984 0.881 0.708–0.941
 AWI 0.953 0.927–0.970 0.798 0.689–0.869
 PWI 0.974 0.958–0.983 0.910 0.861–0.942
Postoperative radiograph
 LCAE 0.978 0.965–0.985 0.889 0.829–0.928
 AI 0.983 0.974–0.989 0.921 0.877–0.949
 AWI 0.975 0.962–0.984 0.829 0.737–0.889
 PWI 0.975 0.961–0.984 0.856 0.775–0.907

The wall indices (AWI and PWI) showed a slightly but noticeably lower values for ICC in the intraoperative reading. However, intra- and interobserver correlation of all parameters was excellent