Table 2.

The comparison of LOD of some newly different developed luminol-based luminophores for analysis of H2O2.

ECL System LoD and Notable Observations Ref
Luminol immobilized on graphite as a paste electrode 0.7 × 10−8 μM; two nearly neutral samples spiked with 3% and 6% H2O2. [176]
Luminol nitrogen doped GQDs 1 × 10−8 M; detection in water samples. [185]
Luminol-H2O2; Flow injection analysis system with ECL detection 3.0 × 10−9 mol/L LoD equal to the level of CL; human serum samples. [186]
Luminol based on synchronous dual sensitization of ECL by using TiNTs and platinum black. 66 pM (H2O2), 22 nM (resveratrol), and 30 nM (dopamine); human serum samples. [187]
Luminol-based ECL system and fluorine-doped tin oxide making use of electrode modified with Au nanoparticles 8 nM; Living cell samples. [188]
Luminol-capped AuNP-modified electrode 1 × 10−7 mol L−1 [189]