Skip to main content
. 2023 Jun 14;13(12):2056. doi: 10.3390/diagnostics13122056

Table 2.

The existing DL models on inferior alveolar nerve and their function and performance.

Authors DL
Models
Year Training Dataset Validation/Test Dataset Functions Best Performance of DL Time-
Consuming
Grana
et al. [35]
CNN 2022 68 8 for validation
15 for test
IAN
detection
IoU: 0.45
DSC: 0.62
No
Kaski
et al. [36]
CNN 2020 128 IAN
detection
Precision: 0.85
Recall: 0.64
DSC: 0.6
(roughly)
No
Song
et al. [37]
CNN 2021 83 50 IAN
detection
0.58 ± 0.08 86.4 ± 61.8 s
Hwang
et al. [38]
3D U-Net 2020 102 IAN
detection
Background accuracy: 0.999
Mandibular canal accuracy: 0.927
Global accuracy: 0.999
IoU: 0.577
No
Nalampang
et al. [39]
CNN 2022 882 100 for
validation
150 for test
IAN
detection
Accuracy: 0.99 No
Jacobs
et al. [40]
CNN 2022 166 30 for validation
39 for test
IAN
detection, relationship between IAN and the third molar
Precision: 0.782
Recall: 0.792
Accuracy: 0.999
DSC: 0.774
IoU: 0.636
HD: 0.705
21.2 ± 2.79 s
Fu
et al. [41]
CNN 2022 154 30 for validation
45 for test
IAN detection, relationship between IAN and the third molar
  • The third molar

Accuracy: 0.9726
DSC: 0.9730
IoU: 0.9606
  • Mandibular canal

Accuracy: 0.9563
DSC: 0.9248
IoU: 0.9003
6.1 ± 1.0 s for segmentation
7.4 ± 1.0 s for classifying
relation
Yi
et al. [42]
Canal-Net 2022 30 20 for validation
20 for test
IAN
detection
Precision: 0.89 ± 0.06
Recall: 0.88 ± 0.06
DSC: 0.87 ± 0.05
Jaccard index: 0.80 ± 0.06
Mean curve distance: 0.62 ± 0.10
Volume of error: 0.10 ± 0.04
Relative volume difference: 0.14 ± 0.04
No
Shin
et al. [43]
CNN 2022 400 500 IAN
detection
Precision: 0.69
Recall: 0.832
DSC: 0.751
F1 score: 0.759
IoU: 0.795
No