Skip to main content
. 2023 Jun 15;12(12):4073. doi: 10.3390/jcm12124073

Table 3.

PCI-related findings.

Non/Mild Calcification (n = 171) Moderate/
Severe Calcification (n = 94)
p Matched Non/Mild Calcification (n = 81) Matched Moderate/Severe Calcification (n = 72) p
Vascular Access 0.002 0.019
Radial 85.38% (146) 69.15% (65) 85.19% (69) 69.44% (50)
Femoral 14.62% (25) 30.85% (29) 14.81% (12) 30.56% (22)
Pre-dilation 97.08% (166) 97.87% (92) 0.699 98.77% (80) 98.61% (71) 0.933
Pre-Stent-Balloon type 0.103 0.269
Semi-compliant balloon 94.74% (162) 90.43% (85) 0.182 97.53% (79) 90.28% (65) 0.057
Non-compliant balloon 2.34% (4) 3.19% (3) 0.679 1.23% (1) 2.78% (2) 0.492
Stent-balloon 0% (0) 1.06% (1) 0.177 0% (0) 1.39% (1) 0.287
Scoring balloon 0% (0) 3.19% (3) 0.019 0% (0) 4.17% (3) 0.064
Pre-dilation balloon diameter size (mm) 2.57 ± 0.37 2.64 ± 0.38 0.208 2.58 ± 0.35 2.62 ± 0.39 0.457
Pre-dilation balloon length (mm) 17.51 ± 2.53 16.61 ± 2.68 0.008 17.24 ± 2.52 17.01 ± 2.88 0.612
Pre-dilation balloon maximum pressure (atm) 11.62 ± 3.03 12.48 ± 2.93 0.029 11.96 ± 3.12 12.28 ± 3.11 0.531
Pre-dilation balloon maximum diameter (mm) 2.68 ± 0.37 2.76 ± 0.38 0.101 2.69 ± 0.32 2.74 ± 0.39 0.420
Plaque modification 0% (0) 4.26% (4) 0.007 0% (0) 4.17% (3) 0.064
Rotablator 0% (0) 1.06% (1) 0.177 0% (0) 0% (0) N/A
Scoring balloon 0% (0) 3.19% (3) 0.019 0% (0) 4.17% (3) 0.064
Stent diameter size (mm) * 3.35 ± 0.51 3.21 ± 0.50 0.034 3.28 ± 0.47 3.25 ± 0.53 0.673
Stent length size (mm) * 26.00 (22.00,34.00) 30.00 (22.00,34.00) 0.062 26.00 (22.00,34.00) 30.00 (26.00,37.00) 0.113
Number of stents per lesion 1.07 ± 0.26 1.16 ± 0.37 0.038 1.09 ± 0.28 1.14 ± 0.35 0.306
Total stent length (mm) 26.00 (22.00,34.00) 30.00 (22.00,38.00) 0.010 26.00 (22.00,34.00) 30.00 (26.00,38.00) 0.062
Stent-balloon maximum pressure at deployment (atm) * 13.99 ± 2.84 13.18 ± 2.58 0.022 13.62 ± 2.85 13.35 ± 2.77 0.554
Stent maximum diameter at deployment (mm) * 3.42 ± 0.52 3.24 ± 0.52 0.008 3.34 ± 0.47 3.28 ± 0.56 0.487
Post-dilation 62.57% (107) 77.66% (73) 0.012 65.43% (53) 80.56% (58) 0.036
Post-dilation balloon type 0.072 0.151
Semi-compliant balloon 1.75% (3) 3.19% (3) 0.452 1.23% (1) 1.39% (1) 0.933
Non-compliant balloon 57.89% (99) 72.34% (68) 0.020 64.20% (52) 77.78% (56) 0.066
Stent-balloon 2.92% (5) 2.13% (2) 0.699 0% (0) 1.39% (1) 0.287
Post-dilation balloon diameter size (mm) 3.61 ± 0.53 3.39 ± 0.44 0.005 3.58 ± 0.51 3.43 ± 0.44 0.100
Post-dilation balloon length (mm) 12.32 ± 3.92 12.84 ± 3.76 0.377 11.42 ± 3.55 12.83 ± 3.82 0.047
Post-dilation balloon maximum pressure (atm) 16.70 ± 3.67 16.38 ± 3.31 0.554 16.72 ± 4.00 16.34 ± 2.93 0.575
Post-dilation balloon maximum diameter (mm) 3.71 ± 0.52 3.48 ± 0.44 0.003 3.69 ± 0.50 3.52 ± 0.45 0.072

* If a lesion was implanted with multiple stents, stent diameter size, stent length size, stent maximum pressure at deployment, and stent maximum diameter at deployment were derived from the parameters of the stent with the largest diameter size.