Table 3.
ILR-detected events, symptoms, and medical interventions.
| RM-ON, N = 133 | RM-OFF, N = 108 | |
|---|---|---|
| ILR-detected events | ||
| Sinus arrest/bradycardia | 13 (9.8%) | 5 (4.6%) |
| AV block | 19 (13.3%) | 9 (8.3%) |
| Atrial fibrillation | 4 (3.0%) | 5 (4.6%) |
| PSVT | 1 (0.75%) | 3 (2.8%) |
| VT | 1 (0.75%) | 0 (0.0%) |
| Asymptomatic | 24 (18.0%) | 8 (7.4%) |
| Medical interventions | ||
| Pacemaker implantation | 25 (18.8%) | 14 (13.0%) |
| PSVT ablation | 1 (0.8%) | 2 (1.8%) |
| AADs initiation | 1 (0.7%) | 1 (0.9%) |
| AADs adjustment | 2 (1.5%) | 3 (2.8%) |
| OACs initiation | 0 (0%) | 2 (1.8%) |
AV: atrio-ventricular; ILR: implantable loop recorder; PSVT: paroxysmal supraventricular tachycardia; RM: remote monitoring; VT: ventricular tachycardia; AADs: antiarrhythmic drugs; OACs: oral anticoagulants