Skip to main content
. Author manuscript; available in PMC: 2024 Feb 16.
Published in final edited form as: Br J Ophthalmol. 2024 Jan 29;108(2):211–216. doi: 10.1136/bjo-2022-322470

Table 2.

ICC, RMSE, Sw, and TRV of VF and OCT/OCTA parameters in the stable eye cohort (max follow-up = 1.5 years)

24-2 VF ICC (95% CI) RMSE (dB) Sw (dB) TRV (dB)
 MD 0.91 (0.88, 0.93) 0.92 0.81 2.24
 PSD 0.93 (0.90, 0.95) 0.75 0.53 1.45
OCTA ICC (95% CI) RMSE (%) Sw (%) TRV (%)
 wiVD 0.82 (0.75, 0.87) 1.64 1.48 4.10
 pfVD 0.80 (0.73, 0.85) 1.80 1.61 4.46
OCT ICC (95% CI) RMSE (μm) Sw (μm) TRV (μm)
 wiGCC 0.99 (0.99, 0.99) 0.91 0.78 2.16
 pfGCC 0.99 (0.99, 1.00) 0.91 0.75 2.08

Abbreviations: ICC = intra-class correlation; MD = mean deviation; OCT = optical coherence tomography; OCTA = optical coherence tomography angiography; pfGCC =parafoveal ganglion cell complex; pfVD = parafoveal vessel density; PSD = pattern standard deviation; RMSE = root mean squared error; Sw, within-subject test–retest standard deviation; TRV = test-retest variability; VF = visual field; wiGCC = whole-image ganglion cell complex; wiVD = whole-image vessel density