Skip to main content
. 2023 Jun 19;4:1150264. doi: 10.3389/fpain.2023.1150264

Table 3.

Reference accuracy results obtained with different features from each sensor and in combination, the number of features appears in parentheses.

Task Model PPG (80) EDA (12) RESP (30) ALL (122)
LDA 81.1±14 92.8±7 71.6±6 89.5±13
No Pain, Pain SVM 82.9±11 93.1±10 71.8±4 93.1±10
DTC 76.7±16 88.5±11 63.4±10 92.0±10
LDA 53.9±11 64.3±14 44.7±10 66.4±13
Multiclass SVM 53.2±10 67.8±16 46.2±9 67.2±14
DTC 47.5±10 59.3±13 38.4±9 56.5±13
LDA 49.1±5 49.8±8 50.4±8 49.8±6
Pain Location SVM 50.9±5 47.8±6 51.3±8 51.4±8
DTC 53.1±10 49.9±8 50.3±6 48.6±7