Skip to main content
. 2023 Jul 4;94:342–347. doi: 10.2340/17453674.2023.13793

Table 2.

Associations between use of tourniquet and cumulative 90-day incidence of VTE in 16,250 procedures from 2010 to 2017

OR (CI) P value
Fisher’s exact test 0.62 (0.38–1.0) 0.056
Mixed Model 1: Use of tourniquet a 0.62 (0.38–1.0) 0.054
Mixed Model 2: Duration of inflation, per 10 minutes a 1.1 (0.97–1.1) 0.2
a

Mixed model adjusting for BMI, age, and history of VTE as fixed factors and hospital as a random factor, reference level = no tourniquet.