. 2023 Jul 10;24:23. doi: 10.1186/s40510-023-00475-2

Table 2.

Comparison of forces and moments generated by direct printed aligners of the 5 tested groups on the UL1

Force Group 1 Group 2 Group 3 Group 4 Group 5 P valuea
Median IQR Median IQR Median IQR Median IQR Median IQR
Fx 1.44 1.22–1.80 1.00 0.78–1.17 1.01 0.86–1.15 1.04 0.89–1.21 0.90 0.76–1.05 < 0.001
Fy − 0.27 − 0.64 to 0.03 − 0.51 − 0.75 to − 0.26 − 0.24 − 0.55–0.14 − 0.25 − 0.46 to 0.00 − 0.23 − 0.48 to 0.08 < 0.001
Fz 0.12 − 0.10 to 0.25 0.11 0.03–0.21 0.14 0.01–0.27 0.19 − 0.04–0.33 − 0.03 − 0.17 to 0.14 < 0.001
Mx 5.97 2.29–8.08 0.75 − 0.85 to 3.48 4.06 0.86–5.97 2.02 0.08–4.06 0.11 − 2.74 to 2.56 < 0.001
My 8.96 7.69–11.33 4.95 3.33–6.11 6.10 4.55–8.55 7.35 6.40–8.30 6.16 4.69–7.58 < 0.001
Mz − 20.74 − 25.71 to − 18.19 − 11.26 − 12.81 to − 9.05 − 14.98 − 16.28 to − 13.17 − 12.67 − 16.57 to − 10.78 − 11.89 − 15.00 to − 9.28 < 0.001

P valuea—overall p value for the model