Skip to main content
. 2023 Jun 28;11(27):10130–10141. doi: 10.1021/acssuschemeng.3c02226

Table 2. Values of Performance Variables for the No (M1), Simplistic (M2), and Full (M3) Channel Model, with a Variable Current Density itot = [50–250 mA cm–2]a.

Model Vcell [V] FEC2H4 [-] χhet [-] χhom [-]
M1 3.69 0.7028 0.506 0.006
M2 f(itot) f(···) f(···) 0.13b
M3 f(itot) f(···) f(···) f(···)
a

Performance variables which are dependent on more than one other variable are denoted as f(···).

b

With a fixed additional current density (ihom = 50 mA cm–2) and a single channel gas flow rate of 10 sccm, for more details see section S1.