Skip to main content
. 2023 Jun 24;9(7):e17632. doi: 10.1016/j.heliyon.2023.e17632

Table 5.

ANOVA statistical results of the response surface quadratic model for turbidity removal.

Source Sum of Squares df Mean Square F-value p-value
Model (Quadratic) 27.16 9 3.02 45.26 <0.0001 significant
A-PAC dosage 2.98 1 2.98 44.64 0.0003
B-CPAM dosage 2.1 1 2.1 31.51 0.0008
C-pH 0.3784 1 0.3784 5.67 0.0487
AB 14.14 1 14.14 211.99 <0.0001
AC 0.5041 1 0.5041 7.56 0.0285
BC 0.09 1 0.09 1.35 0.2834
A2 2.27 1 2.27 34.06 0.0006
B2 1.39 1 1.39 20.84 0.0026
C2 3.65 1 3.65 54.67 0.0002
Residual 0.4668 7 0.0667
Lack of Fit 0.2125 3 0.0708 1.11 0.4419 not significant
Pure Error 0.2543 4 0.0636
Corrected Total Sum of Squares 27.63 16
Coefficient of variance (CV, %) 0.26
R2 0.9831
Adjusted R2 0.9614
Predicted R2 0.8626
Adequate precision 26.53