Table 2. Analytical Parameters of MIP-Based Chemosensors for GLP Determination.
| functional monomer | cross-linking monomer | polymerization method | signal transduction technique | properties | ref |
|---|---|---|---|---|---|
| Acrylamide | EGDMA | T-FRP | Optical | LDCR: 5–40 μg/mL | (103) |
| LOD: 0.046 μg/mL | |||||
| N-Isopropylacrylamide | BAA | T-FRP | Optical | LDCR: 0.005–50 μg/mL | (98) |
| LOD: 0.002 μg/mL | |||||
| 3-(4-Sulfonylbutyl)-1-[3-(triethoxysilyl) propyl]-1H-imidazolium | TEOS | Sol–gel polycondensation | Optical | weLDCR: 0.1 nM - 800 μM | (94) |
| LOD: 0.1 nM | |||||
| N-Methacryl-l-cysteine | EGDMA | FRP, electropolymerization | Electrochemical | LDCR: 3.98–176.24 ng/mL | (96) |
| LOD: 0.35 ng/mL | |||||
| Pyrrole | Electropolymerization | Electrochemical | LDCR: 1 pM – 10 μM | (95) | |
| LOD: 1 pM | |||||
| p-Aminothiophenol | Electropolymerization | Electrochemical | LDCR: 1 pg/L–1 μg/L | (91) | |
| LOD 0.8 pg/L | |||||
| Pyrrole | Electropolymerization | Electrochemical | LDCR: 5–800 ng/L | (102) | |
| LOD: 0.27 ng/mL | |||||
| Pyrrole | Electropolymerization | Electrochemical | LDCR: 400–1200 ng/L | (100) | |
| LOD: 92 ng/mL | |||||
| Pyrrole | Electropolymerization | Electrochemical | LDCR: n/a | (143) | |
| LOD: n/a | |||||
| Acrylic acid and N-vinyl-2-pyrrolidone | DHEBA | Electropolymerization | Electrochemical | LDCR: 0.025–500 μM | (144) |
| LOD: 4 nM |