Skip to main content
. 2023 Jun 21;28(13):4903. doi: 10.3390/molecules28134903

Table 3.

Research studies of ACP on food allergen mitigation.

Food Allergen Mitigation
Allergens Plasma Device Sample Types Antibody Binding
Capacity
Parameters Reference
Exposure Time (min) Exposure Distance (mm) Input Power Input Voltage (kV) Frequency
Casein Plasma jet
(spark discharge)
Allergenic protein solution ↓ 49.9% 30 2.5 - 8 25 kHz [44]
α-lactalbumin ↓ 49.5%
β-lactoglobulin ↑ 250% 10
Casein Plasma jet
(glow discharge)
↓ 91.1% 30 5 - 5 25 kHz
α-lactalbumin ↓ 45.5%
β-lactoglobulin ↑ 300% 10
β-lactoglobulin DBD Allergenic protein solution ↓ 58.21% 4 - - 40 12 kHz [45]
Ara h 1 Plasma jet
(pin-to-plate)
Whole peanut ↓ 39.32% 60 70 - 32 52 kHz [46]
Defatted peanut flour ↓ 65%
Ara h 2 Whole peanut ↓ 46%
Defatted peanut flour ↓ 66%
β-conglycinin (Gly m5) Plasma jet Soy protein isolate ↓ 89% 90 - 12 kW - 2.45 GHz [47]
Glycinin DBD Allergenic protein solution ↓ 91.64% 5 50 40 20 kHz [48]
↓ 81.49% *
Soy allergens DBD Soy protein isolate ↓ 75% * 5 35 - 40 120 Hz [49]

↑—increase; ↓— decrease; *—The binding capacity of IgE antibodies.