Table 2.
List of environmental tests performed on detectors.
| UV | Thermal Cycling/Humidity (RH: Room Humidity) |
High-Temperature Storage (HTS) | Vacuum | Radiations | |
|---|---|---|---|---|---|
| Foundry A | 96 h at 0.6 solar unity | 500 h at 70 °C and 70% RH + 50 cycles (−55 °C/125 °C) under nitrogen and atmospheric pressure | 1000 h at 100 °C | 1 week at <10−6 Torr | 50 MeV protons up to 2 × 1011 p/cm2 |
| Foundry B | 96 h at 0.6 solar unity (B.1 and B.2) | 500 h at 70 °C and 70% RH + 50 cycles (−55 °C/125 °C) under nitrogen and atmospheric pressure (B.1 and B.2) | 1000 h at 100 °C (B.1 and B.2) | Co60 100 krad (B.3 and B.4) Co60 600 Mrad (B.5) 10 keV Xrays 1 Grad (B.5) |
|
| Foundry C | 500 cycles −55 °C/125 °C + 500 h at 70% RH and 70 °C (C.1) | 2000 h at 125 °C (C.1) | 49.7 MeV protons up to 2 × 1012 p/cm2 (C.1) Co60 1 Mrad (C.2) Co60 50 krad (C.3) |
||
| Foundry D | 500 cycles −55 °C/125 °C + 500 h at 70% RH and 70 °C | 2000 h at 125 °C | |||
| Foundry E | Co60 100 Mrad | ||||
| Foundry F | 49.7 MeV protons up to 1 × 1011 p/cm2 Co60 10 krad |