Table 6.

RMS Calibration Measurement Uncertainty within Naturally Ventilated Shields.

Sensor Shield Uncertainty (±°C) Calib. Sensor Reference
Stv. Wood a 0.20 asp. PRT b [168]
Stv. PVC a 0.19 asp. PRT [168]
HOBO (25 avg) c 0.43 asp. PRT [90]
CRS d 0.53 asp. PRT [31]
MMTS e 0.25 asp. PRT [31]
MMTS f 0.28 asp. thermistor [32]
Gill g 0.26 asp. PRT [31]
Gill h 0.45 asp. PRT [171]
Custom Plate h 0.49 asp. PRT [171]
Gill h 0.36 asp. Therm. i [171]
Custom Plate h 0.40 asp. Therm. i [171]
Thermocouple k 2.20 Sonic Anem. j [36]
R. M. Young k 2.95 Sonic Anem. j [36]
MMTS k,l 0.31 asp. CRN m [172]
Stv. Wood (lg) 0.24 asp. PRT [68]
Stv. Wood (sm) 0.23 asp. PRT [68]

a Wooden or polyvinylchloride Stevenson screen. b aspirated platinum resistance thermometer. c Average of 25 naturally ventilated shields. d Cotton region shelter. e Min–max temperature system. f over a snow-covered surface. g PRT, Gill plate shield. h thermocouple. i aspirated thermocouple wire. j sonic anemometer. k Over a snow-covered surface at 2700 m on Alpine Plaine Morte Glacier, Switzerland. l December–February day–night average error scaled to reflect 10 daylight hours at Lincoln, NB, USA (40°48′00″ N; 96°40′00.012″ W). m Standard Climate Research Network aspirated shield.