Table 6.
RMS Calibration Measurement Uncertainty within Naturally Ventilated Shields.
Sensor Shield | Uncertainty (±°C) | Calib. Sensor | Reference |
---|---|---|---|
Stv. Wood a | 0.20 | asp. PRT b | [168] |
Stv. PVC a | 0.19 | asp. PRT | [168] |
HOBO (25 avg) c | 0.43 | asp. PRT | [90] |
CRS d | 0.53 | asp. PRT | [31] |
MMTS e | 0.25 | asp. PRT | [31] |
MMTS f | 0.28 | asp. thermistor | [32] |
Gill g | 0.26 | asp. PRT | [31] |
Gill h | 0.45 | asp. PRT | [171] |
Custom Plate h | 0.49 | asp. PRT | [171] |
Gill h | 0.36 | asp. Therm. i | [171] |
Custom Plate h | 0.40 | asp. Therm. i | [171] |
Thermocouple k | 2.20 | Sonic Anem. j | [36] |
R. M. Young k | 2.95 | Sonic Anem. j | [36] |
MMTS k,l | 0.31 | asp. CRN m | [172] |
Stv. Wood (lg) | 0.24 | asp. PRT | [68] |
Stv. Wood (sm) | 0.23 | asp. PRT | [68] |
a Wooden or polyvinylchloride Stevenson screen. b aspirated platinum resistance thermometer. c Average of 25 naturally ventilated shields. d Cotton region shelter. e Min–max temperature system. f over a snow-covered surface. g PRT, Gill plate shield. h thermocouple. i aspirated thermocouple wire. j sonic anemometer. k Over a snow-covered surface at 2700 m on Alpine Plaine Morte Glacier, Switzerland. l December–February day–night average error scaled to reflect 10 daylight hours at Lincoln, NB, USA (40°48′00″ N; 96°40′00.012″ W). m Standard Climate Research Network aspirated shield.