Skip to main content
. 2023 Jul 6;23(13):6194. doi: 10.3390/s23136194

Table 4.

SY-net mask evaluation results obtained with the COCO2017 dataset.

Method FPS mAP AP50 AP75 APS APM APL
Mask-R-CNN 8.6 35.7% 58.0% 37.8 15.5% 38.1% 52.4%
FCIS 6.0 29.5% 51.5% 30.2% 8.0% 31.0% 49.7%
RetinaMask 4.7 36.6% 55.4% 36.9% 14.3% 36.7% 50.5%
YOLACT 33.5 29.8% 48.5% 31.2% 9.9% 31.3% 47.7%
SY-net (ours) 16.2 33.7% 55.3% 34.9% 16.5% 36.0% 52.7%