Table 3. Experimentally Determined Rate Constants by Performing Global Fit on Transient Spectroscopy Data Using Eq 62.
| material | k1 | k2 | k3 | method | ref. |
|---|---|---|---|---|---|
| MAPbI3 | 15 × 106 | 0.6 × 10–10 | 1.6 × 10–28 | TRTS | (497) |
| MAPbBr3 | 27 × 106 | 4.9 × 10–10 | 13.5 × 10–28 | TA | (578) |
| FAPbI3 | 0.9 × 106 | 7.0 × 10–10 | 3.0 × 10–28 | TRPL, PLQY | (401) |
| FAPbBr0.55I0.45 | 45 × 106 | 17 × 10–10 | 0.4 × 10–28 | TRTS | (516) |
| FA0.9Cs0.1PbI3 | 1.1 × 106 | 0.9 × 10–10 | 7.2 × 10–28 | TRPL, PLQY | (582) |
| (MA0.17FA0.83)Pb(I0.83Br0.17)3 | 10 × 106 | 0.8 × 10–10 | – | TRPL | (523) |