Table 3.
Solvent consumption for one and two consecutive CCC runs in co-current mode (ccCCC). The respective amount of solvent was calculated with 52 min in co-current (cc) flow per run, with an Sf value of 88%, a coil volume of 236 mL and Fm = 2 mL/min and Fs = 4 mL/min in tail-to-head mode
| ccCCC runs | Lower phase | Upper phase | ||
|---|---|---|---|---|
| Coil loading [mL] | cc flow [mL] | Equilibration [mL] | cc flow [mL] | |
| 1x | 236 | 208 | 29 | 104 |
| 2x | 236 | 416 | 29 | 208 |
| ∑1x | 444 mL | 133 mL | ||
| ∑2x | 652 mL | 237 mL | ||