Skip to main content
. Author manuscript; available in PMC: 2023 Oct 1.
Published in final edited form as: J Magn Reson Imaging. 2023 Jan 18;58(4):1055–1064. doi: 10.1002/jmri.28602

TABLE 5.

Deep Learning Computer-Assisted Detection Algorithm Results

CL-bpMRI DL-bpMRI Difference (CI) P
Patient based
 Sensitivity 0.71 0.71 0.00 (−0.21, 0.19) 1.00
 Specificity 0.59 0.44 −0.14 (−0.30, −0.00) 0.05 *
 PPV 0.23 0.24 0.01 (−0.05, 0.06) 0.25
 NPV 0.88 0.88 0.01 (−0.12, 0.09) 0.48
Lesion based
 Sensitivity 0.59 0.53 −0.06 (−0.31, 0.22) 0.73
 Specificity 0.58 0.42 −0.16 (−0.28, −0.04) 0.03 *
 PPV 0.19 0.14 −0.05 (−0.18, 0.05) 0.42
 NPV 0.62 0.57 −0.05 (−0.17, 0.05) 0.05 *

CL-bpMRI = conventional biparametric MRI; DL-bpMRI = deep learning based biparametric MRI; PPV = positive predictive value; NPV = negative predictive value.

*

Significant difference.