Skip to main content
. 2023 Jul 17;23:495. doi: 10.1186/s12903-023-03136-2

Table 2.

UL1 No attachment or pressure column groups comparison by material type

Force ATMOS® TC-85 Zendura FLX® P-value1 P-value2 P-value3
Mean Std Dev Mean Std Dev Mean Std Dev
Fx (N) 10.20 2.93 1.40 0.32 6.00 3.17  < 0.001  < 0.001  < 0.001
Fy (N) -25.22 3.25 -0.67 0.28 -24.61 4.46  < 0.001  < 0.001  < 0.001
Fz (N) 0.94 16.91 0.41 0.17 -24.09 26.58  < 0.001  < 0.001  < 0.001
Mx (Nmm) -130.83 211.30 4.68 2.09 -436.64 329.79  < 0.001  < 0.001  < 0.001
My (Nmm) 54.99 110.75 6.98 1.52 -112.44 173.27  < 0.001  < 0.001  < 0.001
Mz (Nmm) -29.12 62.59 -14.04 2.93 33.60 41.49  < 0.001  < 0.001  < 0.001

P-value1 is a comparison between ATMOS® vs TC-85

P-value2 is a comparison between TC-85 vs Zendura FLX®

P-value3 is a comparison between ATMOS® vs Zendura FLX®