UR1 No attachment or pressure column groups comparison by material type

Force ATMOS® TC-85 Zendura FLX® P-value1 P-value2 P-value3
Mean Std Dev Mean Std Dev Mean Std Dev
Fx (N) 2.00 0.41 0.47 0.18 2.15 0.98  < 0.001  < 0.001  < 0.001
Fy (N) -3.16 2.88 -3.77 2.00 -3.27 5.39  < 0.001  < 0.001  < 0.001
Fz (N) -0.20 1.00 -0.48 0.22 -0.21 0.65  < 0.001  < 0.001  < 0.001
Mx (Nmm) -2.88 5.75 -13.26 5.04 -6.80 10.75  < 0.001  < 0.001  < 0.001
My (Nmm) 5.15 3.85 2.29 2.76 1.13 8.32  < 0.001  < 0.001  < 0.001
Mz (Nmm) 50.24 36.51 46.93 23.16 47.98 58.73  < 0.001  < 0.001  < 0.001

P-value1 is a comparison between ATMOS® vs TC-85

P-value2 is a comparison between TC-85 vs Zendura FLX®

P-value3 is a comparison between ATMOS® vs Zendura FLX®