UR1 Pressure column groups comparison by material type

Force ATMOS® TC-85 Zendura FLX® P-value1 P-value2 P-value3
Mean Std Dev Mean Std Dev Mean Std Dev
Fx (N) 1.51 1.28 0.15 0.16 2.43 0.36  < 0.001  < 0.001  < 0.001
Fy (N) -4.77 3.71 -2.59 1.20 -0.54 1.66  < 0.001  < 0.001  < 0.001
Fz (N) 1.91 2.71 -0.63 0.32 0.00 0.64  < 0.001  < 0.001  < 0.001
Mx (Nmm) -8.85 12.15 -6.06 5.90 -1.41 6.63  < 0.001  < 0.001  < 0.001
My (Nmm) -2.96 17.53 0.52 1.95 0.88 4.80  < 0.001  < 0.001  < 0.001
Mz (Nmm) 78.64 51.26 34.34 13.30 21.04 19.66  < 0.001  < 0.001  < 0.001

P-value1 is a comparison between ATMOS® vs TC-85

P-value2 is a comparison between TC-85 vs Zendura FLX®

P-value3 is a comparison between ATMOS® vs Zendura FLX®