Table 3. PV system model parameters [33].
PV module specifications | |
Item | Value |
P m | 350 W |
V m | 38.5 V |
I m | 9.09 A |
A | (1.984 ×0.998) = 1.98 m2 |
PV array specifications | |
No. PV Modules in series | 2 Modules |
No. of strings | 10 Modules |
Total power of PV system | 7000 W |
Input irradiance (Fixed) | 1000 W/m2 |
Buck converter specifications | |
Capacitor (C) | 5.309e-3 F |
Inductance (L) | 1.16634e-5 H |
V ripple | 1% of Vout (4.3 V) |
Load resistance (PEM electrolyzer) | 0.26414 Ω |
Series resistance to load | 0.09 Ω |
MPPT type | P&O MPPT |