Skip to main content
. 2023 Jul 20;14:4365. doi: 10.1038/s41467-023-40041-2

Table 1.

Cryo-EM data collection, refinement, and validation statistics

HcKCR1 HcCCR
Data collection and processing
  Microscope FEI Titan Krios FEI Titan Krios
  Detector Falcon 4i Falcon 4i
  Magnification (Å) 75,000 75,000
  Voltage (kV) 300 300
  Electron exposure (e2) 40 40
  Defocus range (μm) 0.8–2.4 0.8–2.4
  Pixel size (Å) 1.03 1.03
  Symmetry imposed C3 C3
  Initial particle images (no.) 2,685,194 2,674,318
  Final particle images (no.) 297,015 296,840
  Map resolution (Å) 2.88 2.84
  FSC threshold 0.143 0.143
  Map resolution range (Å) 2.4–3.3 2.4–3.2
Refinement
Initial model used ab initio ab initio
Map sharpening B factor (Å2) −158.5 −153.1
Model composition (monomer)
 Nonhydrogen atoms 2330 2284
 Protein residues 240 240
 Lipids 8 9
 Water 15 15
B factors (Å2)
 Protein 65.80 58.81
 Lipids 71.57 62.23
 Water 68.73 54.52
R.m.s. deviations
 Bond lengths (Å) 0.003 0.003
 Bond angles (°) 0.449 0.447
Validation
 MolProbity score 1.06 1.20
 Clashscore 2.50 1.73
 Poor rotamers (%) 0 0
Ramachandran plot
 Favored (%) 97.90 95.38
 Allowed (%) 2.10 4.62
 Disallowed (%) 0 0