Skip to main content
. 2023 Jun 19;199(12):1284–1294. doi: 10.1093/rpd/ncad178

Table 3.

Airborne TnP uncorrected with bias (BiasEECTn) and corrected for mine draft airflow bias (CorrEECTn) measured with deposition detectors at some Fen complex mine localities, and compared with measured 220Rn, the equilibrium factor, F, with the ones most similar to another mine study in bold

Nr Mine Type Bedrock BiasEECTn (Bq m−3) CorrEECTn (Bq m−3) Biased F Corr F
16 Main adit adita R w/I 760 98 0.134 0.017
17 Main adit adit R w/I 320 42 0.047 0.006
18 Hov adit R w/I 580 76 0.188 0.024
19 Bolla adit R, I, FDC 88 11 0.025 0.003
20 Søve adit F mix 150 19 0.067 0.009
a