Skip to main content
. 2023 Jun 9;9(6):e17145. doi: 10.1016/j.heliyon.2023.e17145

Table 5.

Load deflection behaviour characteristics.

Group Beam T, oC Stiffness, kN/mm Toughness, kN.mm DF SF PF STF TF
1 FB1T23-0-E 23 28.9 1116 2.57 1.18 3.02 1.00 1.00
FB1T23-400-E 32.6 1452 2.89 1.19 3.43 1.13 1.30
FB1T23-600-E 34.7 1665 3.06 1.20 3.67 1.20 1.49
FB1T23-800-E 37.1 1983 3.28 1.25 4.09 1.29 1.78
2 FB2T23-0-I 23 28.9 1116 2.57 1.18 3.02 1.00 1.00
FB2T23-400-I 34.1 1713 3.33 1.20 4.01 1.18 1.54
FB2T23-600-I 40.2 2439 4.12 1.25 5.13 1.39 2.19
FB2T23-800-I 46.2 3446 5.07 1.29 6.56 1.60 3.09
3 FB3T150-0-I 150 22.6 845 2.43 1.17 2.83 1.00 1.00
FB3T150-400-I 27.0 1119 2.71 1.19 3.23 1.14 1.26
FB3T150-600-I 32.1 1545 3.03 1.21 3.67 1.35 1.74
FB3T150-800-I 37.3 2193 3.49 1.28 4.47 1.57 2.47
4 FB4T250-0-I 250 19.6 655 2.29 1.14 2.60 1.00 1.00
FB4T250-400-I 23.7 859 2.48 1.14 2.84 1.09 1.18
FB4T250-600-I 28.2 1155 2.74 1.16 3.16 1.30 1.59
FB4T250-800-I 32.7 1703 3.24 1.23 3.98 1.50 2.34
5 FB5T500-0-I 500 15.6 478 2.21 1.06 2.35 1.00 1.00
FB5T500-400-I 19.0 629 2.34 1.10 2.58 1.06 1.15
FB5T500-600-I 22.9 807 2.47 1.12 2.77 1.28 1.47
FB5T500-800-I 26.6 1023 2.63 1.15 3.03 1.48 1.86

Note: DF: Ductility factor, SF:Strength factor, PF: Performance factor = Ductility factor × Strength factor, TF: Toughness factor, STF: Stiffness factor.