Skip to main content
. 2023 Jul 21;13:11788. doi: 10.1038/s41598-023-38653-1

Table 1.

Sensitivity analysis of the input parameters for the baseline configuration of Ni=80, Na=80, Lrate=25, ld=10 mm, Lerror=2 ms.

Parameters Values RMSE (ms) Total execution time (min)
Ni 20 0.95 ± 0.31 1.81 ± 0.30
400 0.95 ± 0.31 5.80 ± 0.54
Na 20 1.20 ± 0.42 1.55 ± 0.12
400 0.86 ± 0.22 6.68 ± 1.75
Lrate 10 0.95 ± 0.33 2.85 ± 0.55
40 0.91 ± 0.32 2.36 ± 0.17
ld 5 mm 1.10 ± 0.66 3.39 ± 0.34
15 mm 1.18 ± 0.43 1.69 ± 0.15
Lerror 1 ms 0.90 ± 0.33 2.54 ± 0.32
5 ms 1.30 ± 1.06 2.56 ± 0.32
Baseline 0.95±0.31 2.50±0.31

The mean and standard deviation of the RMSE (milliseconds) at the PVJ sites and the total execution time (minutes) to generate the networks are listed.