Skip to main content
. 2023 Jul 21;13:11788. doi: 10.1038/s41598-023-38653-1

Table 2.

Sensitivity analysis of the Na input parameter considering the baseline configuration.

Parameters Values RMSE (ms) Total execution time (min)
Na 80 0.95 ± 0.31 1.78 ± 0.28
120 0.88 ± 0.30 2.39 ± 0.41
160 0.88 ± 0.27 2.89 ± 0.60
200 0.86 ± 0.22 3.39 ± 0.79
240 0.86 ± 0.22 3.79 ± 1.00
280 0.86 ± 0.22 4.33 ± 1.17
320 0.86 ± 0.22 4.86 ± 1.38
360 0.86 ± 0.22 5.45 ± 1.55
400 0.86 ± 0.22 5.99 ± 1.75
Baseline 0.95±0.31 1.78±0.28

The mean and standard deviation of the RMSE (milliseconds) at the PVJ sites and the total execution time (minutes) to generate the networks are listed.