Skip to main content
. 2023 Jan 31;18(8):1533–1541. doi: 10.1007/s11548-023-02832-2

Table 1.

Automated registration and alignment measurement results for 10 patients

Patient Registration Vertebrae Mbone (mm) Mvas (mm)
1 Global L3 L2 2.0 17.0
Local L5 L4 0.5 11.0
2 Global L5 L4 3.0 7.0
Local L3 L2 0.0 5.0
3 Global L5 L4 1.8 16.0
Local L5 L4 0.0 13.0
4 Global L5 L4 2.5 5.0
Local L5 L4 0.0 4.0
5 Global* L3 L2 1.5 9.0
Local L3 L2 1.5 9.0
6 Global L1 T12 2.5 3.0
Local L3 L2 0.5 2.0
7 Global L3 L2 1.3 1.0
Local L5 L4 1.0 1.0
8 Global* L1 T12 0.0 4.0
Local L1 T12 0.0 4.0
9 Global L5 L4 0.8 11.0
Local L3 L2 0.0 6.0
10 Global* L1 T12 1.0 17.0
Local L5 L4 1.0 14.0
Median global 1.6 8.0
min/max (0–3.0) (1.0–17.0)
Median local 0.3 5.5
min/max (0–1.0) (1.0–14.0)

Total median results are highlighted in bold

Displaying registration type (first a global registration is performed followed by a local registration), vertebrae pair, bone alignment (Mbone) and vascular alignment (Mvas)

*Manual adjustment needed