Skip to main content
. Author manuscript; available in PMC: 2024 Aug 1.
Published in final edited form as: Am J Ophthalmol. 2023 Feb 21;252:213–224. doi: 10.1016/j.ajo.2023.02.013

Table 2:

Factors associated with poor outcomes after plasma exchange

Better than 20/200 (n=316) 20/200 or worse (n=81) P-value
Female 72% 63% 0.12
White 68% 69% 0.84
Median Age (years) 35.0 (IQR 27–51) 46.1 (IQR 31–46.1) 0.002
Median visual acuity at time of plasma exchange Count fingers (IQR, 20/400-HM) LP (IQR, HM-LP) <0.001
Median weeks to plasma exchange 2.4 (IQR, 1.4–3.8) 3.3 (IQR, 2.3–3.5) <0.001

Abbreviations: hand motion (HM), light perception (LP), interquartile (IQR)