Skip to main content
. 2023 Jun 23;15(6):e40856. doi: 10.7759/cureus.40856

Table 2. Test of homogeneity of variances using Levene’s test (α=0.05).

Sig.: level of significance

If p>α, the variances of the populations are homogenous.

Phase Levene statistic df1 df2 Sig.
In vitro clot lysis at 90 minutes 3.032 5 30 0.025
In vitro clot lysis at 1200 minutes 3.107 5 30 0.022
In vivo 6.637 5 12 0.003