Skip to main content
. 2023 May 6;22(4):1313–1332. doi: 10.1007/s10237-023-01721-6

Table 5.

Default fixed parameters for windkessel circulatory and LA elastance model, as obtained from (Shavik et al. 2018)

Parameters Unit Values
Aortic valve resistance, Rao Pamsml-1 6500
Mitral valve resistance, Rmv Pamsml-1 2500
Peripheral vascular resistance, Rper Pamsml-1 80,000
Venous resistance, Rven Pamsml-1 2000
Arterial compliance, Cart Paml 0.033
Venous compliance, Cven Paml 0.4
Resting volume for arterial, Vart,0 ml 580
Resting volume for venous, Vven,0 ml 3600
LA end-systolic elastance,Ees,LA Pa/ml 60
Volume axis intercept from ESPVR,V0,LA ml 10
Scaling factor for EDPVR,ALA Pa 58.67
Exponent coefficient for EDPVR,BLA ml-1 0.049
Time to LA end-systole,tmax,LA ms 200
LA relaxation time constant,τLA ms 25