Table 3.
Defined parameters of test 2 with fluid density of , tenth seconds of test (T1) and 5 s after the test (T2).
P (bar) | V (m/s) | Parameters | Nozzle Diameter 0.5 mm – Salt Water |
|||
---|---|---|---|---|---|---|
T1 |
T2 |
|||||
1.2 | 7.7 | Mean | 0.095 | 0.354 | 0 | 0 |
Stand. deviation | 0.0059 | 0.028 | ||||
2.5 | 12 | Mean | 0.145 | 0.546 | 0 | 0 |
Stand. deviation | 0.0115 | 0.038 | ||||
3.6 | 15.2 | Mean | 0.180 | 0.677 | 0 | 0 |
Stand. deviation | 0.0081 | 0.066 | ||||
4.4 | 17 | Mean | 0.209 | 0.762 | 0 | 0 |
Stand. deviation | 0.0211 | 0.043 | ||||
5.2 | 18.5 | Mean | 0.234 | 0.841 | 0.06 | 0.3 |
Stand. deviation | 0.0175 | 0.098 | ||||
6.6 | 21.6 | Mean | 0.268 | 0.968 | 0.09 | 0.3 |
Stand. deviation | 0.0146 | 0.082 | ||||
7.9 | 24 | Mean | 0.297 | 1.077 | 0.11 | 0.4 |
Stand. deviation | 0.0241 | 0.061 | ||||
9.1 | 26 | Mean | 0.323 | 1.171 | 0.12 | 0.4 |
Stand. deviation | 0.0145 | 0.086 |