Skip to main content
. 2023 Jul 12;9(4):1341–1355. doi: 10.3390/tomography9040107

Table 2.

TKV measurement variation among three expert observers.

Mean TKV (mL) TKV Measurement Variation among Three Expert Observers
Sequence Model * Reader 1 (CZ) Reader 2 (AS) Reader 3 (HD) Average
(%Δ from Mean) **
Coefficient of Variation
(%)
Maximum Difference
(%)
Axial T2 1910 1893 1905 1903 1900 (1.8%) 0.7 [0.3–1.3] 0.7 [0.3–1.4]
Coronal T2 1903 1880 1905 1909 1898 (1.7%) 1.2 [0.7–2.2] 1.3 [0.8–2.4]
Axial T1 1844 1853 1826 1824 1834 (−1.7%) 0.9 [0.5–2.0] 1.1 [0.6–2.2]
Axial SSFP 1872 1870 1875 1880 1875 (0.5%) 0.5 [0.2–1.2] 0.5 [0.2–1.3]
Coronal SSFP 1818 1819 1820 1822 1820 (−2.5%) 0.6 [0.3–1.5] 0.6 [0.3–1.6]
All sequences 1869 1863 1866 1868 1866 (0.0%) 0.8 [0.3–1.5] 0.9 [0.4–1.7]

* Model: the auto-segmentation algorithm; ** Average of the three readers and the percent difference from the mean of all sequences prior to outlier corrections.