TKV measurement variations among five sequences.

Percent Difference of TKV among Every Pair of Sequences (%) *
SD (mL) * CV (%) * Mean SD Min Max
Model 86 5.0 6.0 4.0 0.8 12.4
Reader 1 (CZ) 75 4.1 4.8 3.4 0.6 10.0
Reader 2 (AS) 85 4.9 5.9 3.9 0.9 12.1
Reader 3 (HD) 90 5.1 6.1 4.0 0.9 12.6
Reader mean 82 4.6 5.4 3.6 0.8 11.2