Skip to main content
[Preprint]. 2023 Jul 21:2023.07.19.549533. [Version 1] doi: 10.1101/2023.07.19.549533

Table 1.

MRI acquisition details. See Supplementary Fig. 6 for a schematic of the scanning order and positioning of the imaging slabs.

Anatomy Perfusion Vasculature

Parameter MP2RAGE TSE T2w ASL TOF-MRA
TR (ms) 6000 6000 9000 2861 15
TE (ms) 1.88 3.98 105 14 3.59
TI1/TI2 (ms) 800/2750 983/2940 700/1800
FA1/FA2 () 4/5 6/7 132 70 15
GRAPPA 4 (A-P) 2 (A-P) 2 (F-H) 3 3 (F-H)
No. of slices 192 72 50 32 220
Slice direction Sagittal Sagittal Coronal Sagittal Coronal
Field of view (mm) 256×256 184×184 192×192 192×192 210×210
Matrix size 256×256×192 368×368×144 512×512×50 128×128× 448×448×x440
Resolution (mm) 1×1×1 0.5×0.5×0.5 0.4×0.4×1 1.5×1.5×1.5 0.5×0.5×0.5
Phase partial Fourier 6/8 Off 6/8 6/8
Slice partial Fourier Off 6/8 6/8
Bandwidth (Hz/px) 250 140 90 1698 203
Acquisition time (m:s) 7:14 5:26 4:41 4:49 5:50
Number of runs 1 2 3 8 2

Total acquisition time 1:20:21 (h:m:s)