Skip to main content
. 2023 Jul 28;18(7):e0289291. doi: 10.1371/journal.pone.0289291

Table 3. Self-sampling and self-testing accuracy.

Standard Q   Panbio
  N n % 95% CI N n % 95% CI
Met self-sampling thresholda 333 273 82.0 77.4 86.0 331 261 78.8 74 83.1
Met self-testing threshold 335 276 82.4 77.9 86.3 332 300 90.4 86.7 93.3
Agreement with professional test      
Self-sampling 322 322 100 99 100 325 325 100 100 100
Self-testing 333 332 99.7 98 100 330 330 100 100 100

aThreshold: participant performing all critical steps correctly