Table 2.
Results after using the first hearing aids | Results 6 months after using the hearing aids | P-value | |||
---|---|---|---|---|---|
Mean ± SD | Min/max | Mean ± SD | Min/max | ||
Symmetric hearing loss | |||||
ATMST in noise test with headphone | −3.33 ± 2.06 | −5.8 / 1 | −4.35 ± 1.46 | −6.1/0.5 | 0.035 * |
Symmetric hearing loss with unilateral hearing aids | |||||
ATMST in noise test with free field (S 0 N 0 ) | −0.63 ± 2.1 | −5.8/7.3 | −2.87 ± 1.88 | −5/2.1 | 0.032 * |
ATMST in noise test with free field (S 0 N 270 ) | −2.44 ± 2.07 | −5/2.4 | −4.11 ± 3.97 | −8.5/4.7 | 0.029 * |
Symmetric hearing loss with bilateral hearing aids | |||||
ATMST in noise test with free field (S 0 N 90 ) | −0.62 ± 3.69 | −4.8/6.9 | −1.56 ± 3.44 | −5.9/5.1 | 0.030 * |
ATMST in noise test with free field (S 0 N 270 ) | −2.51 ± 2.2 | −5.3/1 | −3.98 ± 1.72 | −6.1/0.5 | 0.017 * |
ATMST: Adaptive Turkish matrix sentence test; SD: Standard Deviation; Min: Minimum; Max: Maximum;
p < 0.05