Table 2.
Linear fitting results for the embedded temperature sensors. According to Equation (8), the slope of the fitting represents the sensitivity of the sensor. The third column of the table presents the statistical error of the slope of the linear least squares fit.
Sensor | Sensitivity (pm/K) |
Statistical Error (pm/K) |
---|---|---|
T1 | 11 | ±2 |
T2 | 10.1 | ±0.8 |
T3 | 10.0 | ±0.5 |
T4 | 10.1 | ±0.6 |
T5 | 11 | ±1 |
T6 | 11 | ±2 |