Skip to main content
. 2023 Jul 18;23(14):6499. doi: 10.3390/s23146499

Table 4.

Variation rate of micro-strain with temperature changes measured by surface-mounted FBG sensors strain. The temperature compensation has been made with T3 for all the sensors.

Surface-Mounted Sensor Strain
(με/°C)
Variation Rate
(με/°C)
Variation Rate Percentage Difference
(με/°C)
S1 −35 ± 6 0.30 ± 0.02 20%
S2 −164 ± 5 1.41 ± 0.04 4%
S3 10 ± 11 −0.08 ± 0.04 55%
S4 −18 ± 6 0.16 ± 0.03 60%
S5 −80 ± 8 0.66 ± 0.03 9%
S6 −153 ± 8 1.20 ± 0.05 8%
S7 −103 ± 5 0.86 ± 0.03 13%