Skip to main content
. 2023 Jul 17;127(29):14425–14438. doi: 10.1021/acs.jpcc.3c02264

Table 4. Dynamic Viscosity (Centipoise) and Slip Length (Å) Values for Gas Dynamics.

gas μ0 μexpa μdry Div (%) LDGPD LCGWPD Ldry
H2 0.009 0.009 0.007 –24.4 3.94 ± 1.02 4.29 ± 0.52 41.78
He 0.018 0.020 0.013 –29.2 3.16 ± 0.34 4.24 ± 0.67 54.14
Ar 0.028 0.023 0.021 –1.3 1.24 ± 0.32 1.81 ± 0.35 2.98
CH4 0.010 0.011 0.004 –5.0 0.65 ± 0.19 0.94 ± 0.45 8.58
CO2 0.033 0.015 0.014 83.3 0.74 ± 0.13 2.06 ± 0.47 0.65
a

μexp is experimental dynamic viscosity values.103107 μ0 denotes the viscosity of gas from the bulk gas system using the Green–Kubo method. μdry is the viscosity of gas in a dry pyrophyllite. LDGPD denotes the slip length for gas in the DGPD. LCGWPD denotes the slip length for gas in a CGWPD. Ldry denotes the slip length for gas in the dry pyrophyllite. The symbol Div represents the percent difference between the relative viscosities in the maximum partially saturated gas-filled pore width (μ/μ0) and in the dry pore width (μdry0) .