Table 3. Spatial overlap accuracy in the automated quantification of total abnormalities and fibrosis score on the original and converted CT images in each group.

CT patterns Group Spatial overlap accuracy metric
DSC Pixel-wise recall Pixel-wise precision
Original CT (1) Converted CT (2) Difference [(2)-(1)] Original CT (1) Converted CT Difference [(2)-(1)] Original CT (1) Converted CT (2) Difference[(2)-(1)]
Total abnormalities Group 2 0.62 ± 0.23 0.68 ± 0.18 0.06* 0.61 ± 0.25 0.64 ± 0.22 0.04 0.71 ± 0.16 0.79 ± 0.14 0.05*
Group 3 0.63 ± 0.21 0.70 ± 0.19 0.05* 0.64 ± 0.25 0.69 ± 0.24 0.05* 0.75 ± 0.18 0.79 ± 0.15 0.04*
Group 4 0.56 ± 0.21 0.65 ± 0.20 0.06* 0.66 ± 0.22 0.72 ± 0.20 0.06* 0.63 ± 0.26 0.67 ± 0.25 0.04*
Group 5 0.64 ± 0.17 0.68 ± 0.16 0.04* 0.71 ± 0.19 0.73 ± 0.16 0.02 0.65 ± 0.22 0.67 ± 0.21 0.02
Group 6 0.68 ± 0.16 0.73 ± 0.13 0.05* 0.67 ± 0.22 0.72 ± 0.18 0.05* 0.76 ± 0.15 0.79 ± 0.13 0.04
Group 7 0.57 ± 0.19 0.65 ± 0.17 0.08* 0.67 ± 0.20 0.68 ± 0.20 0.01 0.59 ± 0.24 0.69 ± 0.21 0.10*
Fibrosis score Group 2 0.30 ± 0.24 0.65 ± 0.20 0.36* 0.21 ± 0.19 0.62 ± 0.22 0.41* 0.83 ± 0.28 0.78 ± 0.21 -0.03
Group 3 0.45 ± 0.28 0.65 ± 0.24 0.50* 0.36 ± 0.26 0.63 ± 0.25 0.27* 0.84 ± 0.19 0.76 ± 0.23 -0.08*
Group 4 0.46 ± 0.22 0.65 ± 0.19 0.18* 0.39 ± 0.24 0.69 ± 0.21 0.30* 0.76 ± 0.26 0.67 ± 0.26 -0.08*
Group 5 0.42 ± 0.28 0.62 ± 0.23 0.20* 0.34 ± 0.17 0.61 ± 0.24 0.27* 0.76 ± 0.28 0.70 ± 0.21 -0.05
Group 6 0.29 ± 0.31 0.63 ± 0.21 0.34* 0.23 ± 0.27 0.60 ± 0.26 0.37* 0.81 ± 0.29 0.75 ± 0.20 -0.05
Group 7 0.04 ± 0.09 0.64 ± 0.19 0.59* 0.02 ± 0.60 0.58 ± 0.21 0.55* 0.83 ± 0.33 0.78 ± 0.16 -0.02

Data are presented as the mean ± standard deviation of the spatial overlap accuracy metrics of the CT slices.

*Indicates that the difference in the overlap accuracy metrics between (1) and (2) is statistically significant (P < 0.008). P-values were calculated using paired t-tests. Significance level of 0.008 takes into account the Bonferroni correction for multiple tests, The mean pixel-wise precision of the original and converted CT images was calculated for those CT slices for which pixel-wise precision was available for both the original and converted CT images, The difference in pixel-wise precision between the original and converted CT images and its statistical significance were calculated for those CT slices for which pixel-wise precision was available for both the original and converted CT images.

CT = computed tomography, DSC = dice similarity coefficient