Table 3.
Performance of the clinical, ECG, and ensemble prediction models.
| ECG model | Clinical model | Ensemble model | |
|---|---|---|---|
| AUROC | 0.685 (0.675–0.695) | 0.747 (0.739–0.755) | 0.767 (0.758–0.776) |
| Sensitivity | 0.636 (0.586–0.686) | 0.774 (0.761–0.787) | 0.761 (0.738–0.784) |
| Specificity | 0.629 (0.573–0.686) | 0.591 (0.578–0.604) | 0.625 (0.600–0.651) |
| Precision | 0.607 (0.584–0.630) | 0.624 (0.617–0.633) | 0.642 (0.628–0.657) |
| Negative predictive value | 0.665 (0.653–0.677) | 0.748 (0.737–0.759) | 0.749 (0.734–0.765) |
| F1 Score | 0.617 (0.599–0.634) | 0.691 (0.683–0.699) | 0.696 (0.683–0.709) |
AUROC area under the receiver operating characteristic curve.