Table 2.
The statistic uncertainty and systematic uncertainty in this work.
Source of uncertainty | Meaning | Value (%) | |
---|---|---|---|
Experiment conditions | Uncertainty of neutron energy spectrum below 150 keV | 8.00 | |
Uncertainty of neutron energy spectrum above 150 keV | 4.50 | ||
Uncertainty of sample parameter (see Table 1) | < 0.50 | ||
Uncertainty of proton beam power | < 1.50 | ||
Data analysis | Uncertainty from PHWT | < 3.00 | |
Uncertainty of unfolding | < 2.00 | ||
Statistics | Statistic uncertainty | < 2.70 | |
Error propagation | Total uncertainty | < 9.00 |