TABLE II.

Latency and Frame Rate

Setting Device Latency Clock
Frequency
Frame
Rate
Input
Rate
1 ZU5EV 20,500 314.26 MHz 15,330 1.26 GSPS
2 ZU9EG 20,503 304.79 MHz 14,865 2.44 GSPS
3 KU19P 10,259 302.30 MHz 29,466 4.83 GSPS
4 KU19P 20,501 302.76 MHz 14,768 2.42 GSPS