. 2023 Jul 29;47:101246. doi: 10.1016/j.ijcha.2023.101246

Table 3.

Studies reporting Diagnostic Test Accuracy data for cfDNA in AMI.

Author Year Number Outcome to discriminate cfDNA
Troponin
cfDNA quantification method AUC (95%CI), p-value Cut-off, units Sensitivity Specificity AUC (95%CI) Cut-off Sensitivity Specificity
Agiannitopoulos 2020 80 AMI
50 controls
AMI Qubit® 3.0 ssDNA assay 0.99 (0.997–1.00), p < 0.001 20.45 ng/μl 100% 99% 0.94 (0.87–1.00), p < 0.001* NR NR NR
Qubit® 3.0 dsDNA assay 0.94 (0.89–0.98), p < 0.001 3.43 ng/μl 100% 98%
NanoDrop® 0.99 (0.99–1.00), p < 0.001 15.4 ng/μl 100% 92%
qPCR TaqMan Copy Number Reference Assay TERT 0.99 (0.99–1.00), p < 0.001 13.70 ng/μl 100% 99%
Cui 2013 49 AMI
60 controls
ACS branched DNA-based Alu assay 0.98 (0.96–1.00) NR 92% 98% 0.74 (0.68–0.80)** NR 57% 98%
STEMI from ACS branched DNA-based Alu assay 0.90 (0.84–0.95) NR NR NR 0.76 (0.67–0.84)** NR NR NR
Lou 2015 120 AMI
60 controls
AMI Alu-based qPCR assay (Primer size 201 bp) 0.89 (0.82–0.95), p < 0.001 3.71 log copies/ml 77% 96% 0.90 (0.85–0.96), p < 0.001** 1.35 ng/ml 80% 84%
Alu-based qPCR assay (Primer size 170 bp) 0.76 (0.66–0.85), p < 0.001 1.93 log copies/ml 100% 49%
Alu-based qPCR assay (Primer size 147 bp) 0.86 (0.79–0.93), p < 0.001 0.22 log copies/ml 100% 60%
Alu-based qPCR assay (Primer size 113 bp) 0.94 (0.89–0.99), p < 0.001 3.73 log copies/ml 87% 96%
Alu-based qPCR assay (Primer size 76 bp) 0.97 (0.93–1.00), p < 0.001 6.13 log copies/ml 87% 100%
Alu = log (Alu1 + Alu2 + Alu3 + Alu4 + Alu 5) 0.93 (0.87–0.99), p < 0.001 6.40 log copies/ml 92% 96%
Ren 2022 116 AMI
25 controls
AMI methylated CORO6 ddPCR assay 0.68 (0.59–0.78), p = 0.0037 NR NR NR NR NR NR NR
Xie 2018 100 AMI
30 controls
AMI PicoGreen® dsDNA assay 0.96 (0.90–0.99) 110 ng NR NR NR NR NR NR
Zemmour 2018 31 AMI
83 controls
STEMI demethylated FAM101A sequencing-based assay 0.94 (0.90–0.98), p < 0.001 NR NR NR NR NR NR NR

*Cardiac troponin T, **Cardiac Troponin I, NR: Not Reported.