表 1. The strengths and weaknesses of the main D-dimer examination methods available.

目前主要D-二聚体检测方法优缺点[3-5]

Detection method Advantages Disadvantages
Whole-blood agglutination assays Rapid test; point-of-care-testing; sample type: whole blood Low specificity; manual
Latex agglutination assays Rapid test; Automated Intermediate specificity
Latex immunotrurbidimetry High sensitivity; good repeatability; batch test; automated Intermediate specificity
Enzyme-linked immunosorbent assays (ELISA) High sensitivity Low specificit (50%); time-consuming; manual
Enzyme-linked immunofluorescent assays (ELFA) High sensitivity; automated Low-intermediate; high Specificity (70%)
Immune colloidal gold Easy to perform; suitable for emergency treatment Low specificity