Table 4.
3-D Echo measurement (first echocardiographer) | Mean ± SD | r | p-value |
RV-EDV (mL) | |||
First | 80.1 ± 40.6 | ||
Second | 79.9 ± 44.1 | 0.97 | <0.001 |
Third | 83.8 ± 44.2 | ||
RV-ESV (mL) | |||
First | 46.1 ± 33.5 | ||
Second | 46.1 ± 36.3 | 0.98 | <0.001 |
Third | 48.4 ± 38.1 | ||
RV-SV (mL) | |||
First | 34.0 ± 16.8 | ||
Second | 31.5 ± 15.4 | 0.86 | <0.001 |
Third | 34.6 ± 15.6 | ||
RV-EF (%) | |||
First | 44.9 ± 13.8 | ||
Second | 42.8 ± 13.6 | 0.83 | <0.001 |
Third | 44.2 ± 14.0 |
3-D, three-dimensional; EDV, end-diastolic volume; EF, ejection fraction; ESV, end-systolic volume; r, intra-class correlation coefficient; RV, right ventricle; SV, stroke volume.