Skip to main content
. 2021 Sep 3;22(12):929–936. doi: 10.2459/JCM.0000000000001250

Table 4.

Intra-observer variability

3-D Echo measurement (first echocardiographer) Mean ± SD r p-value
RV-EDV (mL)
 First 80.1 ± 40.6
 Second 79.9 ± 44.1 0.97 <0.001
 Third 83.8 ± 44.2
RV-ESV (mL)
 First 46.1 ± 33.5
 Second 46.1 ± 36.3 0.98 <0.001
 Third 48.4 ± 38.1
RV-SV (mL)
 First 34.0 ± 16.8
 Second 31.5 ± 15.4 0.86 <0.001
 Third 34.6 ± 15.6
RV-EF (%)
 First 44.9 ± 13.8
 Second 42.8 ± 13.6 0.83 <0.001
 Third 44.2 ± 14.0

3-D, three-dimensional; EDV, end-diastolic volume; EF, ejection fraction; ESV, end-systolic volume; r, intra-class correlation coefficient; RV, right ventricle; SV, stroke volume.